Prestige Shantiniketan - Specifications
Design Standards
- The development is designed to comply with National Building Codes (NBC) and standards.
Floor Loading
- A typical floor in the building is designed for a load of 400 Kg/sqm with 1 grid on either side of the lift core strengthened to 850 Kg/sqm.
Floor to Floor Height
- 4.05 m with a clear height of 3.535 m.
Screeding
- Average 50 mm thick IPS flooring is provided in all office areas
Elevators
Passenger Lifts -
- Crescent 1 to 4 - 8 nos.
- Tower A, B & C - 8 nos.
- MLCP - 6 nos.
- Make - Mitshubishi
- Carrying Capacity - 20 passengers & 2.55 m/s speed
Service Lifts -
- Crescent 1 to 3 & Tower A & B - 1 no.
- Crescent 4 & Tower C - 2 nos.
- Make - Thyssenkrupp .
- Carrying Capacity - 1500 kg & 1.0 m/s
Sewerage System
- An underground Sewage treatment plant shall be provided and the treated water shall be used for landscaping and flushing purposes.
Facade
- Façade is a combination of double glazing, ACP and textured paint. The glazing comprises of 24mm thick DGU glass with the Outer pane is of 6 mm thick heat strengthened performing glass with 12mm Air gap and an inner pane of 6 mm thick Annealed clear float
Toilet Finishes
- Flooring / Dadoing – Combination of Vitrified / Ceramic Tiles.
- Ceiling – Gypsum False Ceiling.
- CP Fittings - Jaquar
Power
- The development has a 66KV sub station which receives power supply from dual feeders. The transformer capacity for the entire development is 22.5 MVA