Prestige Shantiniketan - Specifications

 Design Standards
  • The development is designed to comply with National Building Codes (NBC) and standards.

 Floor Loading
  • A typical floor in the building is designed for a load of 400 Kg/sqm with 1 grid on either side of the lift core strengthened to 850 Kg/sqm.

 Floor to Floor Height
  • 4.05 m with a clear height of 3.535 m.

 Screeding
  • Average 50 mm thick IPS flooring is provided in all office areas

 Column Grid
  • 10.8 m X 10.8 m c/c.


 Elevators

Passenger Lifts -

  • Crescent 1 to 4     -   8 nos.
  • Tower A, B & C     -   8 nos.
  • MLCP                   -   6 nos.
  • Make                   -   Mitshubishi
  • Carrying Capacity   -  20 passengers & 2.55 m/s speed

Service Lifts -

  • Crescent 1 to 3 & Tower A & B        -  1 no.
  • Crescent 4 & Tower C                     -  2 nos.
  • Make                                            -   Thyssenkrupp .
  • Carrying Capacity                            -  1500 kg & 1.0 m/s

 Sewerage System
  • An underground Sewage treatment plant shall be provided and the treated water shall be used for landscaping and flushing purposes.

 Facade
  • Façade is a combination of double glazing, ACP and textured paint. The glazing comprises of 24mm thick DGU glass with the Outer pane is of 6 mm thick heat strengthened performing glass with 12mm Air gap and an inner pane of 6 mm thick Annealed clear float

 Toilet Finishes
  • Flooring / Dadoing – Combination of Vitrified / Ceramic Tiles.
  • Ceiling – Gypsum False Ceiling.
  • CP Fittings - Jaquar

 Power
  • The development has a 66KV sub station which receives power supply from dual feeders. The transformer capacity for the entire development is 22.5 MVA



Prestige Tech Park
II - Electra
Prestige Tech Park III

This information is conceptual and not a legal offering. The promoter reserves the right to change, alter, add or delete any of the specifications mentioned herein without prior permission or notice.