Prestige Tech Park II - Electra - Specifications

 Design Standards
  • The development is designed to comply with National Building Codes (NBC) and standards.

 Floor Loading
  • A typical floor in the building is designed for a load of 400 Kg/sqm with designated areas strengthened to 1,000 Kg/sqm.

 Floor To Floor Height
  • Office floors have a floor to floor height of 4.05 m whereas the basement has a floor to floor height of 4.45 m.

 Screeding
  • Average 60 mm thick IPS flooring is provided in all office areas

 Column Grid
  • 10.6 m X 10.6 m c/c.
 Elevators
  • Passenger Lifts - Each block shall have 12 nos. passenger lifts having a carrying capacity of 20 passengers.
  • Service Lifts - Each block shall have 2 nos. service lifts having 1,000 kgs carrying capacity.
  • Make - Passenger Lifts for B1: Mitsubishi Service Lifts for B1 & MLCP1: Hyundai
 Fire Fighting and Suppression System
  • As per local fire regulations, comprising of sprinkler system, fire hydrants, hose reels, fire alarm system for common areas, smoke detectors for common areas.

 Sewerage System
  • Underground Sewage treatment plant shall be provided and treated water be used for landscaping and flushing purposes.

 Facade
  • Building façade is a combination of Double Glazing, ACP, stone cladding and masonry with plastering and textured paint.

 Common Area Finishes
  • Lobbies – Granite / Artificial Marble
  • Main Staircase – Kotah Stone / Tiles



Prestige Tech Park III
Prestige Shantiniketan

This information is conceptual and not a legal offering. The promoter reserves the right to change, alter, add or delete any of the specifications mentioned herein without prior permission or notice.